JINFAN WATER / TECHNICAL REFERENCE

JFPS-300L vs JFPS-500L: what changes?

The July 2026 records list 300 L/h and 500 L/h nominal production. Both list a 1550 × 750 × 1750 mm cabinet; net weights are 207 kg and 219 kg respectively.

Specification edition: 15 July 2026 · Prepared by JINFAN WATER from supplied model records.

July 2026 model-specific specifications
ModelNominal productionLength × width × heightNet weight
JFPS-300L300 L/h1550 × 750 × 1750 mm207 kg
JFPS-500L500 L/h1550 × 750 × 1750 mm219 kg

Does 500 L/h mean 500 litres of storage?

No. L/h describes a production rate; L describes a volume. The source descriptions list a 500 L tank for both models. Confirm the tank arrangement and usable storage separately from production capacity.

How should a buyer choose between the two models?

Start with daily treated-water demand and available production hours. For example, 3,000 L/day divided by 10 production hours requires an average 300 L/h. This calculation alone does not establish that JFPS-300L is sufficient: peak use, reserve capacity, feed-water conditions and downtime require review.

Request a quotation for the exact model and configuration, including the tank, distribution system, electrical supply and installation scope. Neither nominal output is a guaranteed on-site result.

Why does the older series page show different dimensions?

The series catalogue and the July 2026 model records describe different source configurations. The older series reference lists 800 × 750 × 1780 mm and 200 kg. Those values should not be combined with the model-specific dimensions and weights above.

Read the source and configuration notes · Plan commercial RO capacity · Discuss your required capacity